Universelles RRC Standard-Batterieladegerät RRC-SMB-UBC mit Ladeschacht.

RRC-SMB-UBC

Standard Battery Charger for SMBus compliant Batteries

  • Single bay fast charger
  • For the standard battery form factors RRC20xx or smart batteries with a similar footprint
  • Optimized charging process for RRC batteries:
    • Longer cycle life
    • Faster charging
  • Simple operation – Plug and Play
  • Automatic recognition and calibration of smart battery learned capacity
  • External power supply for worldwide use
  • Country specific AC input cables available

你需要更多的信息吗?

产品数据表 RRC-SMB-UBC

Specification RRC-SMB-UBC

Input
Voltage range19.00 - 26.00VDC
Current3.40A max.
Power65.00W
Output
Voltage range

0 - 17.40VDC

Current

0 – 4.80A

Voltage tolerance±1% max.
Current tolerance

±10% max. @1A, ±3% max. @4A

Protection

Short circuit, Overtemperature shutdown,
Input / Output overcurrent

Environmental
CoolingConvection cooled
Temperature

Operating: 0°C bis 40°C
Non-operating: -10°C to 70°C

Pressure & Altitude

Operating: 1060hPa to 795hPa (-382m to 2000m)
Non-operating: 1060hPa to 572hPA (-382m to 4570m)

Humidity5% to 95% r.F., non-considering
General
Efficiency~95% to 100% load
Battery type

For standard battery packs in form factor RRC20XX or similar SMBus compliant batteries

Green procurementRoHS 2011/65/EU
WEEE 2012/19/EU
Chinese RoHS
IndicatorMulti-color LED (green, red, orange)
Housing dimensions (LxWxH)151.00 x 90.00 x 43.00mm
Weight198g (without power supply)

One time Red/Orange/Green

Selftest: Charger is ready for use.

Red/Green blinking

Battery recognition and initialization.

Orange blinking

The battery is currently being calibrated.

Orange light

The inserted battery is of the correct type and is currently being charged.

Green light

The battery is charged and can be removed for use.

Red blinking

The battery is too hot or too cold to be charged without damage. If the battery is too cold it will be charged as soon as it has warmed up sufficiently. If the battery is too hot it should be removed to cool down.

Red light

The battery is damaged or it is a conventional battery which cannot be recharged.

 

In combination with included external AC/DC power supply (PS65)

 

Regulatory approvals

EuropeCE

Electromagnetic Emissions

EuropeEN55011, EN55022, level B
 USA & CanadaFCC15, class B

Electromagnetic Immunity

ESD immunityEN/IEC61000-4-2
 Electromagnetic field immunity EN/IEC61000-4-3
 EFT / BurstEN/IEC61000-4-4
 Surge

EN/IEC61000-4-5

 Conducted Immunity

EN/IEC61000-4-6

 Magnetic Fields

EN/IEC61000-4-8

 Voltage dips, short instrumentations & voltage variations

EN/IEC61000-4-11

 Immunity characteristics

EN55024

Specification external AC/DC power supply (PS65)

Input

Voltage range

100 - 240VAC

Current

1.70A max.

Stand by power

No load < 0.50W @ 230.00 VAC

Output
Voltage range

19.00VDC

Power

65.00W max.

Current range

3.40 A

Protection

Over voltage, over current, short circuit

Environmental
Temperature

Operating: 0°C to 40°C
Non-operating: -10°C to 70°C

General
Efficiency

California's Energy Efficiency Level VI

Ripple & Noise

0.30V (p-p)

Standard output connector

DC barrel jack (5.50 x 2.50mm)

Housing dimensions (LxWxH)

95.00 x 51.00 x 25.40mm

Weight

270g

Approvals

EuropeCE
 InternationalCB
 USA & CanadacULus
 

Australia & New Zealand

RCM
 Russia & Eurasian Customs UnionEAC
 KoreaKC
 ChinaCCC
 JapanPSE
 IndiaBIS

Standard Battery Charger RRC-SMB-UBC is approved worldwide